Technical requirements:
Reference standard: GB / T 14579 (IEC 60384-17)
Climate category: 40 / 85 / 56
Rated temperature: 85 ℃
Operating temperature range (shell): - 40 ℃ ~ 85 ℃
Maximum allowable ambient temperature: 70 ℃
Rated voltage: 630vdc ~ 2000vdc
Capacitance range: 0.22uf ~ 9.9uf
Capacitance Deviation: ± 5% (J), ± 10% (k), ± 20% (m)
Withstand voltage: 1.6ur (10s)
Loss tangent: < 0.0005 (20 ℃, 1kHz)
Insulation resistance: < 100 000 m Ω CR < 0.33uf) > 30 000 s CR > 0.33uf (20 ℃, 100V, 1min)